product
- DUOSAFE Technology Highlights
Comfort comes from engineering, safety begins with design
TrueCushion™ Cushioning System and TrueLock™ Safety System are the two core technologies of the DUOSAFE series, focusing on comfort during blood sampling and operational safety, respectively. Through distinct mechanical designs, these technologies are incorporated into DUOSAFE Lancing Devices and Single-Use Safety Lancets, delivering a more consistent, comfortable, and secure lancing experience.
- DUOSAFE Lancing Device / Safety Lancet 機構
Through a multi-guide rail design, the lancet maintains a stable, perpendicular puncture path. Combined with a multi-stage spring mechanism that controls the force during activation, the system reduces vibration and noise during lancing, enhancing both operational stability and user comfort.
- DUOSAFE Safety Lancet Agency
Featuring a 3D contoured pressure-relief design, the system distributes localized pressure at the point of contact between the lancet and the skin, enhancing contact stability and user comfort.
- DUOSAFE Lancing Device organization
Featuring a safety cap locking mechanism, the device can only be cocked when the cap is securely locked in place, reducing the risk of accidental needle contact during operation. Combined with a one-handed lancet ejection mechanism, users can safely remove the used lancet without directly touching the needle.
- DUOSAFE Safety Lancet Agency
The two-stage safety lock helps reduce the risk of accidental activation before the device is ready for use. After activation, the needle automatically retracts and locks securely inside the device, preventing re-exposure of the used needle.
- DUOSAFE Lancing Device (model LD-E1)
Gently enter the needle and exit with peace of mind
Six-stage depth
Safety switch
One-handed needle return
Standard compatible
Anti-blood stain design
Mirror pen body
Six Adjustable Lancing Depth Settings
Large Viewing Window: Allows users to easily select the appropriate penetration depth based on their individual needs.
Safety Cap Locking Mechanism
The device can only be cocked when the cap is securely locked in place, reducing the risk of accidental needle contact during operation.
One-handed needle return
The one-handed lancet ejection mechanism allows users to remove the used lancet without directly touching the needle.
Standard compatible
Compatible with Standard Lancets.
Anti-blood stain design
Featuring an anti-blood contamination design, the device helps minimize the risk of blood residue accumulating inside. An integrated blood barrier helps prevent blood droplets from entering the cap, reducing the risk of internal blood contamination.
Smooth, Mirror-Finish Body
Good grip, easy to clean, smooth mirror surface does not hide dirt, both function and texture
- DUOSAFE Safety Lancet (model MSL1)
Safe, from firing to discarding
3D curved decompression
Fit the blood collection site to disperse the contact pressure
Two-way limit
Prevents activation until the safety tab is removed.
Automatic retraction
The needle automatically retracts and locks securely inside the device.
Six specifications
Model number | color | specification |
|---|---|---|
MSL1-30G | Pink green | 30G |
MSL1-28G | Pink orange | 28G |
MSL1-26G | pink | 26G |
MSL1-23G | Pink blue | 23G |
MSL1-21G | Pink purple | 21G |
MSL1-18G | Goose yellow | 18G |
Specifications and downloads
Specification sheet of each model (PDF) download link